C.E.SRL火焰检测器65UV5系列65UV5-1004ECEX技术参数及介绍

发布日期:2024-05-08 16:06:04

C.E.SRL自1977年以来一直涉足石油和天然气市场(陆上和离岸)、石化、能源生产、化工、加工行业。多年来,已开发出适合阀门和运动部件(活塞、操纵臂、安全门、单元旋转检查等)位置监控领域的各种需求的特定产品。

 

C.E.SRL火焰检测器65UV5系列技术参数

SPECIFICATIONS (CEX   MODEL)

 

MECHANICAL:

 

Housing Weight:

6.6 lbs (2.99kg)

Hazardous   Classifications:

Exd IIC T6 ATEX

Cooling / Purge Air   Requirements:

 

Source:

Clean, dry, cool

Volume:

4 SCFM (113 l/min) at   3/4" threaded mounting flange, or 1 inch “Y” fitting, mounted on scanner   sight pipe.
Temperature near the upper limit of the scanner operating range and/or use   with dirty/dusty fuels may require up to 15 SCFM (425 l/min).

Pressure:

Adequate to overcome   furnace or windbox pressure

Temperature Rating:

-40° F to + 150°F   (-40°C to +65°C) maximum dependent on “T” classification

Humidity:

0% to 95% relative humidity,   non-condensing

ELECTRICAL:

 

Input Power:

24 Vdc, + 20% / - 25%   supply current 100 mA

Electrical Connection:

Internal terminal rail

Relay Output

FLAME RELAY, (N.O.) /   (N.C.) SPDT
  FAULT RELAY, (N.O.) SPST

Contact Rating:

Minimum: 1 mA @ 5 Vdc
Maximum: 2 A @ 30 Vdc
2 A @ 240 Vac

Status Indication:

Internal LED: “Flame   Signal”, “Fault Indication”

Analog Output:

4-20 mA DC current,   referenced to 24 Vdc common, maximum connected load 750 ohms

 

C.E.SRL火焰检测器65UV5系列介绍

65UV5火焰扫描仪是基于微处理器的火焰扫描仪,采用紫外线管式传感器和机电自检快门机制。65UV5火焰扫描仪包含一个具有固定ON/OFF阈值的内部火焰继电器,因此无需外部火焰放大器。

 

65UV5火焰扫描仪由外部提供的24 Vdc电源供电,并包括一个集成的8针快速断开连接器。颜色编码的内部LED指示火焰状态和警报状况。这可以通过后盖上的观察口查看。

 

65UV5外壳具有NEMA 4X / IP66等级。该装置适用于Class 1, Div. 2个危险环境组A、B、C和D或Ex II3 G/D Ex nA IIC T4A。

 

65UV5 CEX型号通过位于CEX外壳内的端子导轨直接接线。必须使用合适的密封套将电缆端接在外壳上。

 

The 65UV5 flame scanner is a microprocessor-based flame scanner utilizing an ultraviolet tube-type sensor and an electro-mechanical self-checking shutter mechanism. The 65UV5 flame scanner incorporates an internal flame relay with a fixed ON/OFF threshold thereby eliminating the need for an external flame amplifier.

 

The 65UV5 flame scanner is powered from a 24 Vdc power source provided externally and includes an integral 8 pin quick disconnect connector. A color-coded internal LED indicates flame status and alarm condition. This can be viewed through a viewing port on the rear cover.

 

The 65UV5 housing has a NEMA 4X / IP66 rating. The unit is suitable for use in Class 1, Div. 2 hazardous environment groups A, B, C & D or Ex II3 G/D Ex nA IIC T4A.

 

65UV5 CEX models are wired directly via a terminal rail located within the CEX housing. Suitable glands must be used to terminate the cable at the housing.

 

C.E.SRL火焰检测器65UV5系列其他常用型号:

C.E.SRL 65UV5-1004

C.E.SRL 65UV5-1004E

C.E.SRL 65UV5-1004QD

C.E.SRL 65UV5-1004QD-1

C.E.SRL 65UV5-1004EQD

C.E.SRL 65UV5-1004ECEX