SENSOREX传感器ODO9000介绍

发布日期:2024-05-10 15:23:19

Sensorex设计和制造pH电极,ORP电极,电导率和TDS传感器,以及其他电化学和光学测量技术。

 

SENSOREX产品有:传感器,控制器,变送器等。

 

 

SPECIFICATIONS

 

Measurement Principle

Optical measurement via luminescence

Measurement Ranges

0.00-20.00 mg/L
0.00-20.00 ppm
0-200%

Accuracy

± 0.1 mg/L
± 0.1 ppm
± 1%

Response Time

90% in less than 60 seconds

Measurement Interval

> 5s

Membrane Cap

Cross Sensitivity: Organic solvents (acetone, toluene, chloroform, methylene chloride); Chlorine gas No Cross Sensitivity: pH 1-14, H2 S, CO2 , SO2

Temperature Compensation

10K NTC

Temperature Accuracy

0.5°C

Sample Temperature

0-50°C (32 to 122°F)

Max Pressure

5 bar (72.5 PSI)

Signal Output

Direct MODBUS RS-485

Power Supply

12 Volts (±1Volt)

Power Consumption

1 W

Dimensions

Diameter: 25 mm (0.98 in) x Length 146 mm (5.75 in)

Weight

450g (1lb) for sensor + 3m (10ft) cable

Material

316 Stainless Steel(ODO8000), Titanium (ODO9000)

Protection Rating

IP68

 

SENSOREX传感器介绍

ODO8000 and ODO9000 - Lumin-S Optical Dissolved Oxygen Sensors with Digital Communication

Product Information

The Lumin-S optical dissolved oxygen sensor delivers reliable DO measurements over a long operating life. There are no membranes to replace, no electrolyte solutions to replenish, and no anodes to clean. Maintaining the sensor is as easy as replacing the optical sensing cap once every 1-2 years, and since all calibration data is stored on the cap, there’s no need to calibrate. This dissolved oxygen sensor outputs a Modbus/RS-485 digital signal for easy PLC integration.

 

Reliable measurements: Optical sensor technology delivers accurate DO monitoring with no drift and no minimum flow

Long operating life with minimal maintenance: No membranes, electrolyte solutions, or anodes – just replace the cap once every 1-2 years

No calibration: All calibration data is stored on the cap for quick and easy startup

Simple system integration: Use Modbus/RS-485 to integrate with a PLC or other control system

 

ODO8000 和 ODO9000 - 具有数字通信功能的 Lumin-S 光学溶解氧传感器

产品信息

Lumin-S 光学溶解氧传感器可在较长的使用寿命内提供可靠的 DO 测量。 无需更换膜,无需补充电解质溶液,也无需清洁阳极。 维护传感器就像每 1-2 年更换一次光学传感帽一样简单,并且由于所有校准数据都存储在帽上,因此无需校准。 该溶解氧传感器输出 Modbus/RS-485 数字信号,以便于 PLC 集成。

 

可靠的测量:光学传感器技术可提供准确的溶解氧监测,无漂移且无最小流量

使用寿命长,维护最少:无需膜、电解质溶液或阳极 - 只需每 1-2 年更换一次盖子

无需校准:所有校准数据都存储在瓶盖上,以便快速轻松地启动

简单的系统集成:使用Modbus/RS-485与PLC或其他控制系统集成

 

SENSOREX传感器常见型号及订货号:

SENSOREX ODO8000

SENSOREX ODO9000